"Use of tank mounted booster pumps for providing NPSH to turbopumps operating in a radiation environment."
Item
Dublin Core
Identifier
Useoftankmounboospump_031607093838.pdf
spc_stnv_000929
Title
"Use of tank mounted booster pumps for providing NPSH to turbopumps operating in a radiation environment."
Description
This paper outlines the results of a test program which was planned to demonstrate the feasibility of using a tank mounted, all-inducer, high speed liquid hydrogen booster pump to provide NPSH for the turbo pump in a reactor-powered vehicle. The cavitation problem associated with pumpoing liquid hydrogen, when used as a propellant, is further aggravated by localized heating caused by radiation from the reactor.
Date
1/1/1962
Temporal Coverage
Source
Saturn V Collection
Box 6, Folder 21
University of Alabama in Huntsville Archives, Special Collections, and Digital Initiatives, Huntsville, Alabama
Language
Rights
This material may be protected under U. S. Copyright Law (Title 17, U.S. Code) which governs the making of photocopies or reproductions of copyrighted materials. You may use the digitized material for private study, scholarship, or research. Though the University of Alabama in Huntsville Archives and Special Collections has physical ownership of the material in its collections, in some cases we may not own the copyright to the material. It is the patron's obligation to determine and satisfy copyright restrictions when publishing or otherwise distributing materials found in our collections.
Relation
spc_stnv_000925_000942
Is Referenced By
http://libarchstor.uah.edu:8081/repositories/2/archival_objects/16708
Collection
Citation
DiStefano, John F. and Borg-Warner Corporation. Pesco Products Division, “"Use of tank mounted booster pumps for providing NPSH to turbopumps operating in a radiation environment.",” UAH Archives, Special Collections, and Digital Initiatives, accessed November 23, 2024, http://libarchstor2.uah.edu/digitalcollections/items/show/10232.